| STEEL WIRE ROPE FOR LIFTS |
| |
|
| Rope:6X19S+Fc
Stand:9+9+1
Strandand:GB8903-88 |
Rope:8X19S+Fc
Stand:9+9+1
Strandand:GB8903-88 |
|
Structure
|
Strandard
|
(mm)
Diameter
|
(kg/100m)
Reference Weight
|
Minimun breaking
force of the Wire rope |
| 1570N/mm2,
1370/1770N/mm2 |
1770N/mm2 |
| 6X19S+Fc |
GB8903-88 |
6 |
13.0 |
17.8 |
21.0 |
| 8 |
23.1 |
31.7 |
37.4 |
| 10 |
36.1 |
49.5 |
58.4 |
| 11 |
43.7 |
59.9 |
70.7 |
| 13 |
61.0 |
83.7 |
98.7 |
| 16 |
92.4 |
127 |
150 |
| 19 |
130 |
179 |
211 |
| 22 |
175 |
240 |
283 |
| 8X19S+Fc |
GB8903-88 |
8 |
22.2 |
28.1 |
33.2 |
| 10 |
34.7 |
44.0 |
51.9 |
| 11 |
42.0 |
53.2 |
62.8 |
| 13 |
58.6 |
74.3 |
87.6 |
| 16 |
88.8 |
113 |
133 |
| 19 |
125 |
159 |
187 |
| 22 |
168 |
213 |
251 |
Note : The main purposes : it uses intensity 1570N/mm2 lift.
Breaking Force calculated according 1570N/mm2 1370/1770N/mm2
minimum. While the implementation of the user units elevator
rope standard protocol standards
| |
|
8×19W+8×7+1×19W |
8×19S+8×7+1×19W |
|
Structure
|
(mm)
Diameter
|
%
|
(kg/100m)
Reference Weight
|
Minimun breaking force of the Wire rope
|
| 1570N/mm2 |
1770N/mm2 |
|
8×19W+8×7+1×19W
8×19S+8×7+1×19W |
8
9
10 |
0
∽ + 4 |
27.00
34.00
42.00 |
36.80
46.60
57.50 |
41.50
52.50
64.80 |
| 11
12
13 |
51.00
61.00
71.00 |
70.00
83.00
97.00 |
78.90
93.60
109.00 |
| 14
15
16 |
82.00
94.00
108.00 |
113.00
129.00
148.00 |
127.00
146.00
167.00 |
| 18
20
22 |
136.00
168.00
203.00 |
186.00
231.00
279.00 |
210.00
260.00
214.00 |
| |
|
9×19S+9×7+Fc |
9×19S+9×7+1×19W |
|
Strucyure
|
(mm)
Diameter
|
%
|
(kg/100m)
Reference Weight
|
Minimun breaking force of the Wire rope
|
| 1570N/mm2 |
1770N/mm2 |
| 纤维芯 |
钢芯 |
纤维芯 |
钢芯 |
纤维芯 |
钢芯 |
|
9×19S+9×7+FC
9×19S+9×7+1×19W |
8
9
10
11 |
0
∽ + 4 |
25.00
33.00
40.00
49.00 |
26.00
35.00
43.00
52.00 |
34.20
46.10
56.10
67.50 |
38.50
51.30
62.70
75.50 |
38.60
52.00
63.30
76.10 |
43.40
57.80
70.70
85.10 |
| 12
13
14 |
57.00
66.00
76.00 |
61.00
71.00
82.00 |
80.00
91.70
106.00 |
89.30
104.00
120.00 |
90.20
103.00
120.00 |
101.00
117.00
135.00 |
| 15
16
17 |
90.00
101.00
118.00 |
96.00
108.00
126.00 |
125.00
140.00
164.00 |
141.00
157.00
184.00 |
141.00
158.00
185.00 |
159.00
177.00
207.00 |
| 18
19
20 |
128.00
141.00
156.00 |
136.00
151.00
167.00 |
178.00
196.00
217.00 |
199.00
219.00
242.00 |
201.00
221.00
244.00 |
224.00
247.00
273.00 |
Note : 1, the above-mentioned categories also produce galvanized
wire rope. 2, anti-pull strength steel users can design. Pre-tensioned
structure more stable elevator rope elongation smaller and
longer life. Pre-tensioned wire rope into the elevator rope
after rope to a certain tension, and maintain a certain amount
of time. Technology lower residual stress and the structure
of elongation. So that the structure more stable, longer life
expectancy, and application of high-level, high-speed elevator.
Companies are welcome to use the lift.
|